科慕(原杜邦)离子膜N115、N117

Du Pont
Material Safety Data Sheet
Page 1
Printed on 03/14/2010
----------------------------------------------------------------------
"NAFION" PFSA MEMBRANES LISTED ON NAF002
NAF002 Revised 8-JUL-2008
----------------------------------------------------------------------
Substance ID : 130000034168
----------------------------------------------------------------------
CHEMICAL PRODUCT/COMPANY IDENTIFICATION
----------------------------------------------------------------------
Material Identification
"NAFION" is a registered trademark of DuPont.
# Tradenames and Synonyms
PFSA Membrane
"NAFION" N115, N117, N1110,
Company Identification
MANUFACTURER/DISTRIBUTOR
DuPont Fluoropolymers
1007 Market Street
Wilmington, DE 19898
PHONE NUMBERS
Product Information : 1-(800)441-7515
Transport Emergency : 1-(800)424-9300
Medical Emergency : 1-(800)441-3637
----------------------------------------------------------------------
COMPOSITION/INFORMATION ON INGREDIENTS
----------------------------------------------------------------------
Components
Material CAS Number %
TETRAFLUOROETHYLENE/PERFLUORO 31175-20-9 100
(4-METHYL-3,6-DIOXA-7-OCTENE-
1-SULFONIC ACID) COPOLYMER
Components (Remarks)
Material is not known to contain Toxic Chemicals under Section 313
of Title III of the Superfund Amendments and Reauthorization Act
of 1986 and 40 CFR part 372.
----------------------------------------------------------------------
HAZARDS IDENTIFICATION
----------------------------------------------------------------------
# Potential Health Effects
ACUTE OR IMMEDIATE EFFECTS: ROUTES OF ENTRY AND SYMPTOMS
INGESTION Not a probable route of exposure.
Print Date: 5 - 26 - 2011
NAF002
Du Pont
Material Safety Data Sheet
Page 2
Printed on 03/14/2010
SKIN Prolonged contact may cause skin irritation to some
individuals.
EYE Reversible cornea opacity and mild conjunctivitis.
INHALATION Not respirable in pellet form. Inhalation of
fumes from overheating or burning "Nafion", or from smoking
tobacco or cigarettes contaminated with polymer dust, may
cause polymer fume fever, a flu-like illness with chills and
fever. Symptoms may not occur for several hours after
exposure and go away in 24-48 hours even in absence of
treatment.
Carcinogenicity Information
None of the components present in this material at concentrations
equal to or greater than 0.1% are listed by IARC, NTP, OSHA or ACGIH
as a carcinogen.
----------------------------------------------------------------------
FIRST AID MEASURES
----------------------------------------------------------------------
First Aid
INHALATION
If exposed to fumes from overheating or combustion, remove to
fresh air.
SKIN CONTACT
The compound is not likely to be hazardous by skin contact but
cleansing the skin after use is advisable.
EYE CONTACT
In case of contact, immediately flush eyes with plenty of water
for at least 15 minutes. Call a physician.
INGESTION
No specific intervention is indicated as compound is not likely to
be hazardous by ingestion. Consult a physician if necessary.
----------------------------------------------------------------------
FIRE FIGHTING MEASURES
----------------------------------------------------------------------
Flammable Properties
Flash Point : NA
Method : NA
Hazardous gases/vapors produced in fire are hydrogen fluoride
(HF), and, organic fluorine compounds.
Print Date: 5 - 26 - 2011
NAF002
Du Pont
Material Safety Data Sheet
Page 3
Printed on 03/14/2010
Extinguishing Media
Water, Foam, Dry Chemical, CO2.
Fire Fighting Instructions
Wear protective clothing and use self-contained breathing
equipment to protect from acidic fluoride fumes.
----------------------------------------------------------------------
ACCIDENTAL RELEASE MEASURES
----------------------------------------------------------------------
Safeguards (Personnel)
NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL)
sections before proceeding with clean-up. Use appropriate
PERSONAL PROTECTIVE EQUIPMENT during clean-up.
Accidental Release Measures
Pick up to avoid slipping hazard.
----------------------------------------------------------------------
HANDLING AND STORAGE
----------------------------------------------------------------------
Handling (Personnel)
See FIRST AID and PERSONAL PROTECTIVE EQUIPMENT SECTIONS.
Storage
Store in a cool, dry place away from flammable materials.
----------------------------------------------------------------------
EXPOSURE CONTROLS/PERSONAL PROTECTION
----------------------------------------------------------------------
Engineering Controls
VENTILATION Local exhaust for operations above 150 C (302 F)
degrees C.
Personal Protective Equipment
EYE/FACE PROTECTION
Wear safety glasses.
Recommended glove material: No information was found for selection
of materials of construction for
protective clothing.
RESPIRATOR
Use a NIOSH approved positive pressure air-supplied respirator if
concentrations may exceed exposure limits. Air purifying
Print Date: 5 - 26 - 2011
NAF002
Du Pont
Material Safety Data Sheet
Page 4
Printed on 03/14/2010
respirators are inadequate for this material.
Exposure Guidelines
Exposure Limits
"NAFION" PFSA MEMBRANES LISTED ON NAF002
PEL (OSHA) : Particulates (Not Otherwise Regulated)
15 mg/m3, 8 Hr. TWA, total dust
5 mg/m3, 8 Hr. TWA, respirable dust
----------------------------------------------------------------------
PHYSICAL AND CHEMICAL PROPERTIES
----------------------------------------------------------------------
Physical Data
% Volatiles : None
Solubility in Water : Insoluble
Odor : None
Form : Membrane
Color : Natural
----------------------------------------------------------------------
STABILITY AND REACTIVITY
----------------------------------------------------------------------
Chemical Stability
Stable at normal temperatures and storage conditions.
Conditions to Avoid
At temperatures above 150 C (302 F), toxic and corrosive
decomposition fumes are liberated.
Incompatibility with Other Materials
None reasonably foreseeable.
Decomposition
HAZARDOUS DECOMPOSITION PRODUCTS - hydrogen fluoride, carbonyl
fluoride, toxic fluoro-organic compounds.
----------------------------------------------------------------------
ECOLOGICAL INFORMATION
----------------------------------------------------------------------
Ecotoxicological Information
AQUATIC TOXICITY:
No information is available. Toxicity is expected to be low based
on insolubility in water.
----------------------------------------------------------------------
DISPOSAL CONSIDERATIONS
----------------------------------------------------------------------
Print Date: 5 - 26 - 2011
NAF002
Du Pont
Material Safety Data Sheet
Page 5
Printed on 03/14/2010
Waste Disposal
Preferred options for disposal are (1) recycling and (2) landfill.
Incinerate only if incinerator is capable of scrubbing out
hydrogen fluoride and other acidic combustion products.
Treatment, storage, transportation, and disposal must be in
accordance with applicable federal, state/ provincial, and local
regulations.
----------------------------------------------------------------------
TRANSPORTATION INFORMATION
----------------------------------------------------------------------
Shipping Information
DOT
Not Regulated.
----------------------------------------------------------------------
REGULATORY INFORMATION
----------------------------------------------------------------------
U.S. Federal Regulations
TSCA Inventory Status : In compliance with TSCA Inventory
requirements for commercial purposes.
State Regulations (U.S.)
STATE RIGHT-TO-KNOW LAWS
No substances on the state hazardous substances list, for the
states indicated below, are used in the manufacture of products on
this Material Safety Data Sheet.
SUBSTANCES ON THE PENNSYLVANIA HAZARDOUS SUBSTANCES LIST PRESENT
AT A CONCENTRATION OF 1% OR MORE (0.01% FOR SPECIAL HAZARDOUS
SUBSTANCES): None known.
WARNING: SUBSTANCES KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM: None known.
SUBSTANCES ON THE NEW JERSEY WORKPLACE HAZARDOUS SUBSTANCE LIST
PRESENT AT A CONCENTRATION OF 1 % OR MORE (0.1% FOR SUBSTANCES
IDENTIFIED AS CARCINOGENS, MUTAGENS OR TERATOGENS): None known.
----------------------------------------------------------------------
OTHER INFORMATION
----------------------------------------------------------------------
Additional Information
MEDICAL USE: CAUTION: Do not use in medical applications
involving permanent implantation in the human body. For other
medical applications see DuPont CAUTION Bulletin No. H-50102.
----------------------------------------------------------------------
Print Date: 5 - 26 - 2011
NAF002
Du Pont
Material Safety Data Sheet
Page 6
Printed on 03/14/2010
The data in this Material Safety Data Sheet relates only to the
specific material designated herein and does not relate to use in
combination with any other material or in any process.
Responsibility for MSDS : L. W. BUXTON
Address : DUPONT FLUOROPRODUCTS
CHESTNUT RUN PLAZA 713
WILMINGTON, DE 19880-0713
Telephone : 302-999-4658
# Indicates updated section.
End of MSDS
Print Date: 5 - 26 - 2011

上海邦强国际贸易有限公司

业务:13331888921 史先生

售后服务:021-60658277

运营综合:021-60658276

电话传真:021-60658278

 

网络传真:4008266163-05277

客服/投诉QQ:1974194078

客服/投诉邮箱:sjm@shh-bangqiang.com

网址:http://www.shh-bangqiang.com

地址:上海市普陀区真北路2167号鸿海大厦802室

行业应用

 


上海邦强国际贸易有限公司